To sterilise nail tools properly you need an autoclave — cleaning and disinfecting are different processes, and only sterilising makes an instrument safe to use on broken skin. If you run a nail service in NSW, the distinction is not a matter of preference — it decides which tools you may reuse and which must go in the bin.

This guide sets out what NSW Health actually requires, in the order you would do it in a salon.

The three levels, and what each one does

Process What it does Typical nail tools
Cleaning Physically removes visible soil, dust, oil and product. It is the first step, never the last. Everything, before anything else
Disinfecting Reduces the number of micro-organisms on a surface. It does not make an item sterile. Files, buffers, work surfaces, tool handles
Sterilising Destroys all micro-organisms, including spores. Required for anything that can break the skin. Cuticle nippers, any sharp instrument

The practical rule is simple: you cannot sterilise a dirty instrument. Cleaning always comes first, and the standard is explicit that “equipment must be thoroughly cleaned” before processing.

What must be sterile

NSW Health’s nail treatment fact sheet states plainly that “all articles that penetrate the skin must be sterile before use”. In a nail service that mainly means cuticle nippers and any instrument sharp enough to draw blood, intentionally or not.

Two further points follow from the sterilising guidance:

  • Instruments must “be kept in a sterile condition until used in a skin penetration procedure” — so a sterilised tool left loose in a drawer is no longer sterile.
  • If a package comes out of the autoclave wet, “the package contents are deemed unsterile and must be reprocessed before use”.

There is also a standing recommendation worth taking seriously: equipment that is difficult to clean and sterilise should simply be single-use.

How to sterilise nail tools, step by step

Five steps, in this order. Skipping one invalidates the rest.

1. Clean. Remove all visible residue. Ultrasonic cleaners are useful here — but note what NSW Health says about them below.

2. Dry. “Instruments must be properly dried” before they go any further.

3. Package and label. “Instruments must be packaged and labelled prior to placing in an autoclave.” Packaging is what keeps the instrument sterile after the cycle ends; an unwrapped tool is sterile only until it touches air and surfaces.

4. Run the cycle. Sterilisation must be carried out in a steam-under-pressure benchtop autoclave, “in line with AS 5369:2023”. NSW Health adds that “it is recommended that a Type S or B autoclave is purchased” and that “the autoclave should be registered by the Therapeutic Goods Administration (TGA)”.

5. Record it. Covered in its own section below, because it is the step most salons get caught on.

What does not sterilise nail tools

This is the section to read twice, because several of these appear in salons marketed as sterilisers. NSW Health lists the following as things that do not sterilise instruments:

  • UV light cabinets
  • Microwave ovens
  • Pasteurisers
  • Disinfectants
  • Boiling
  • Ultrasonic cleaners — the guidance is explicit: “ultrasonic cleaners clean but do not sterilise instruments”

A UV cabinet is a storage box. It is not a sterilising step and cannot substitute for one. If a supplier sells you a glass-bead or UV unit as a steriliser, that claim does not meet the NSW standard for skin-penetrating instruments.

Ultrasonic cleaners are genuinely useful — they belong at step 1, not step 4.

Files, buffers and e-file bits

These are not skin-penetrating equipment, so the sterilising rule does not apply — but they are not exempt either. NSW Health’s nail fact sheet requires that files and buffers “need to be cleaned and disinfected after use on each client”, and states that “it is recommended that single-use equipment is used”.

In practice salons run one of two systems:

  • Single use — the file goes in the bin after the appointment.
  • One client, one file — labelled with the client’s name, stored in a closed clean container, used only on that client.

A porous foam buffer that has been used on someone else cannot be wiped clean. If you are choosing grits for your kit, our guide to nail file grit covers which ones are worth buying as single-use. For metal and carbide e-file bits, which can be cleaned properly, see which e-file bit does what.

Gloves and hand hygiene

NSW Health requires “single-use gloves during skin penetration procedures”. Sterile instrument tips must not be handled with bare hands — where sterile equipment has to be touched, “a pre-packed sterile alcohol swab, a sterile dry swab, or single-use gloves must be used”.

Hands must be washed before and after attending to a client, before and after a procedure, after contact with body substances, “after touching a client’s surroundings”, and after removing gloves. Gloves are an addition to hand washing, not a replacement for it.

How long must sterilisation records be kept?

Twelve months. NSW Health states that “sterilisation records must be kept for 12 months”.

That means recording each cycle — not just owning an autoclave. A record that cannot be matched to a date and a load is of little use if an inspector asks for it, and it is the single most common gap found in small salons.

A practical set-up checklist

  • Register the business with your local council before opening — NSW Health states “the business must be registered with the local council”, and that premises must also meet planning and building requirements.
  • Buy a benchtop steam autoclave, Type S or B, TGA-registered, and run it to AS 5369:2023.
  • Set up a cleaning step before the autoclave — clean, then dry, then package and label.
  • Keep a sterilisation log and retain it for 12 months.
  • Decide your file and buffer policy: single-use, or labelled per client in a closed container.
  • Stock single-use gloves and use them for any skin-penetrating work.
  • Store packaged sterile instruments so the packaging stays intact and dry until use.

If you are setting up at home rather than in a shopfront, the council requirements differ in detail — our guide to home beauty salon requirements in NSW covers that side.

The short version

Clean everything. Disinfect what touches intact skin. Sterilise anything that can break skin, in a packaged load in a TGA-registered autoclave, and write down that you did. UV cabinets, boiling and disinfectant soaks are not sterilising, whatever the packaging says.

Sources: NSW Health, How to sterilise instruments; NSW Health, Nail treatment fact sheet.